DRY VACUUM PUMPS

DRY VANE (DVV)

Vacuum Pumps > Dry Vacuum Pumps > Dry Vane

Technical Documentation

7-177 cfm / 24-27″HgV / 0.5-10HP

DVV 10

Capacity CFM / m3/h: 7/12
Pressure “HgV / Torr 25.5/150
Motor HP / RPM: 0.6/1750

DVV 16

Capacity CFM / m3/h: 11/19.2
Pressure “HgV / Torr 25.5/150
Motor HP / RPM: 1/1750

DVV 25

Capacity CFM / m3/h: 18/30
Pressure “HgV / Torr 25.5/150
Motor HP / RPM: 1.5/1750

DVV 40

Capacity CFM / m3/h: 28/48
Pressure “HgV / Torr 25.5/150
Motor HP / RPM: 2/1750

DVV 60

Capacity CFM / m3/h: 39/72
Pressure “HgV / Torr 27/75
Motor HP / RPM: 2.5/1750

DVV 100

Capacity CFM / m3/h: 69/120
Pressure “HgV / Torr 27/75
Motor HP / RPM: 5/1750

DVV 140

Capacity CFM / m3/h: 93/168
Pressure “HgV / Torr 27/75
Motor HP / RPM: 7.5/1750

DVV 200

Capacity CFM / m3/h: 128/217
Pressure “HgV / Torr 24/150
Motor HP / RPM: 7.5/1150

DVV 250

Capacity CFM / m3/h: 177/300
Pressure “HgV / Torr 24/150
Motor HP / RPM: 10/1150

DRY CLAW

 DRY CLAW VACUUM PUMP > Dry Vacuum Pumps > Dry Claw

Technical Documentation

69-353 cfm / 24-27″HgV / 3-15HP

KCP 1000 HV

Capacity CFM / m3/h: 69/117
Pressure “HgV / Torr 27.5/60
Motor HP / RPM: 3/3600

KCP 1500 HV

Capacity CFM / m3/h: 113/192
Pressure “HgV / Torr 27.5/60
Motor HP / RPM: 5/3600

KCP 2500

Capacity CFM / m3/h: 181/307
Pressure “HgV / Torr 24/150
Motor HP / RPM: 7.5/3600

DRY-C 160

Capacity CFM / m3/h: 113/192
Pressure “HgV / Torr 25.5/112.5
Motor HP / RPM: 5/3600

DRY-C 250

Capacity CFM / m3/h: 177/300
Pressure “HgV / Torr 24/150
Motor HP / RPM: 7.5/3600

DRY-C 300

Capacity CFM / m3/h: 212/360
Pressure “HgV / Torr 24/150
Motor HP / RPM: 10/3600

DRY-C 400

Capacity CFM / m3/h: 283/480
Pressure “HgV / Torr 24/150
Motor HP / RPM: 12/3600

DRY-C 500

Capacity CFM / m3/h: 353/600
Pressure “HgV / Torr 24/150
Motor HP / RPM: 15/3600

DRY SCREW (DRY-VAC)

 DRY SCREW VACUUM PUMP

Technical Documentation

58-440 cfm / 29.92″HgV / 7.5-30HP

DRY-VAC 100

Capacity CFM / m3/h: 58/99
Pressure “HgV / Torr 29.72/5
Motor HP / RPM: 7.5/3500

DRY-VAC 200

Capacity CFM / m3/h: 115/195
Pressure “HgV / Torr 29.9/0.2
Motor HP / RPM: 10/3500

DRY-VAC 300

Capacity CFM / m3/h: 170/289
Pressure “HgV / Torr 29.92/0.1
Motor HP / RPM: 15/3500

DRY-VAC 400

Capacity CFM / m3/h: 230/391
Pressure “HgV / Torr 29.92/0.02
Motor HP / RPM: 20/3500

DRY-VAC 800

Capacity CFM / m3/h: 440/748
Pressure “HgV / Torr 29.92/0.01
Motor HP / RPM: 30/3500

BORA (LOBE)

Technical Documentation

70-3250 m3/hr / 0.5-0.001 mbarA / 2-125HP

BORA 103 AC – 883 AC Exhausters

Capacity m3/hr: 225 – 1800
Pressure mbar(A): 150 – 1013
Motor HP / RPM: 10 to 60/2150

BORA 243 FP – 2313 FP Vacuum Boosters

 Capacity CFM : 41 – 377
Pressure mbar(A): 0.5 – 1013
Motor HP / RPM: 2 to 10/2850

BORA 73 HV – 1083 HV Vacuum Boosters

Capacity m3/hr: 205 – 3250
Pressure mbar(A): 0.001 – 1013
Motor HP / RPM: 3 to 20/2850

BORA 73F – 883F Positive Displacement Blowers

Capacity m3/hr: 35 – 2610
Pressure mbar(A): 500 – 1013
Motor HP / RPM: 15-125/2150